Home › Portfolio Lighting Parts › Portfolio Lighting Model Parts Directory: Transformers, Fixtures, Sensors & Repair Parts

📦Shop Portfolio-Compatible Lighting Parts on AmazonAffiliate link · We may earn a commission.🔧Find Discontinued Portfolio Parts on eBayAffiliate link · We may earn a commission.

Portfolio Lighting transformer and control checks

Use this Portfolio Lighting Model Parts Directory: Transformers, Fixtures, Sensors & Repair Parts guide alongside the label on your existing Portfolio transformer or control. Record the model number, electrical ratings and timer or photocell arrangement before selecting replacement parts or changing the wiring.

Portfolio owner’s first step: Start by confirming outlet power and GFCI status, then identify the exact Portfolio unit; never assume a similarly shaped replacement has compatible ratings.

Portfolio transformer troubleshootingIdentify your Portfolio modelPortfolio troubleshootingPortfolio replacement parts

Specialist Resource

Can't find your exact Portfolio model?

The 104-page Master Handbook includes legacy specs and modern replacement paths for discontinued systems.

$9.99

GET THE PDF

How This Parts Directory Works

If your system isn’t working at all or you’re not sure where the failure is, start with the Portfolio lighting troubleshooting guide. It walks through the exact steps I use to isolate issues quickly.

Identifying specific internal components for older fixtures can be a challenge, especially for discontinued units. For a comprehensive breakdown of technical specifications and wiring layouts, you can refer to our Portfolio Lighting Master Model & Replacement Handbook, which catalogs over 100 specialized models in one digital guide.

What You See What It Usually Means What To Do First Lights won’t turn on Transformer, GFCI, or photocell issue Check power source, then test output voltage Lights stay on all day Photocell failure or sensor blockage Clean or replace photocell Flickering lights Voltage drop, bad connector, or failing LED driver Test voltage at fixture and inspect connections One fixture not working Bad socket, stake, or connector Test voltage at that fixture only System worked before but now failing Loose connection, corrosion, or overload Check terminal lugs and wiring layout

Critical insight: Most Portfolio systems fail at connectors, photocells, or terminal lugs—not the fixtures themselves.

Additional exact-identifier parts research

PF-4300-BK motion light: sensor, mounting, lamp and fault diagnosis explains how to distinguish a detector or setting issue from a supply, weather-seal or lamp fault before buying an unverified replacement. For battery-powered landscape fixtures, SLL12BK solar light: battery chemistry, panel, dusk detection and stakes explains why voltage, charging circuit and mechanical measurements matter more than visual resemblance. Both pages mark specifications that still require label confirmation.

New model-specific parts records

New documented parts research: power packs and deck lights

Portfolio EE3394BK 200-Watt Landscape Power Pack: The 200-watt manual explains why load, voltage drop and wire routing must be checked before replacing a transformer.

Portfolio 00752 Deck Light: The original package list identifies a preassembled connector, mounting cleat, anchors and two different screw groups—useful when reconstructing missing deck hardware.

More exact-identifier parts research: 0092251 and 0098920

For a power pack with identifier 0092251, the 0092251 power-pack parts and cable diagnosis guide explains nameplate verification, branch faults and replacement checks. For the indexed 0098920 spotlight, use the 0098920 spotlight lamp, lens, stake and connector guide before purchasing a lookalike part. Both manual-index leads require confirmation against the physical equipment label.

Additional model-specific parts research

The Portfolio 00848 / 0104292 path-and-spotlight kit guide explains how to separate transformer, cable, connector and individual fixture replacements when only the kit number survives. For an individual accent fixture, the Portfolio 0688493 spotlight guide covers lamp access, lens measurements, water seals, aiming joints and cable faults. Confirm the actual component markings before ordering.

I built this as a practical repair directory because homeowners usually do not search a model number for trivia. They search it because something broke.

The best repair path starts by naming the part correctly. A transformer problem is not fixed with a new path light. A bad photocell is not fixed by replacing the whole yard. A broken stake does not require throwing away a working fixture head. That is the purpose of this page.

You can also browse common replacements in the Portfolio lighting parts and accessories guide.

If you want a deeper breakdown of older models and hard-to-find components, I recommend browsing the Portfolio technical archive. This is where I document discontinued models, rare parts, and real-world repair patterns I’ve seen over time.

Finding Parts Is Only Half the Repair Process

A replacement part is only useful when the failed component has been correctly identified. Many Portfolio Lighting repairs stall because homeowners replace bulbs when the transformer is failing, replace transformers when a connector is shorted, or replace entire fixtures when only an LED driver has failed. Before ordering components from this directory, review documented transformer failure patterns, perform LED bypass testing for integrated fixtures, and use Portfolio Lighting AI assistance to compare symptoms, evaluate compatibility and identify the most likely repair path for your specific model.

Identify the Portfolio transformer before making changes

Read the model label for input and output ratings, maximum connected load, and any timer or photocell controls. Older Portfolio transformer generations can differ; do not select a replacement by wattage alone.

Portfolio model lookup Portfolio transformer troubleshooting Portfolio installation instructions

Where to Find Your Model Number

In my experience, most labels are faded or missing. Before guessing, check these locations:

If you still can’t find it, match the fixture style and failure type—this directory is designed for that.

Most Common Portfolio Failure Points

Component Failure Type Fix Photocell Lights stay on or off Replace sensor Terminal lugs Loose or corroded connections Clean or replace lugs Connector clips No “bite” into wire Use waterproof wire nuts LED driver Flickering or dim output Replace driver or fixture Transformer No output or overload Test input/output voltage

Quick Search: Full Model Number Index

If you need full specifications for your exact unit, including voltage, wattage, and compatibility details, use the Portfolio lighting model specs directory to match your model before ordering parts.

If you want a deeper breakdown of how each model actually performs and fails in real-world use, see the Portfolio lighting model library, specifications, and repair index. I use that page to map specs, failure patterns, and repair paths across multiple models.

Before ordering replacement parts, use the Portfolio Lighting Master Model Technical Database to confirm the exact model family, electrical profile, and compatible part direction.

Tap a model number to jump straight to the repair card. If your exact number is not listed, use the closest category first, then use the contact link at the bottom of any card to send the issue.

#121408200W Transformer #SL-200-12200W Manual Transformer #0312384120W Transformer #009511545W Transformer #BT-150-12150W Power Pack #YL-56-12Low Voltage Power Supply #EPC-1Remote Photocell #0688503LED Landscape Path Light #FS130125-7Outdoor Wall Light #155153Outdoor Lantern #0012351Post Light #LD1702ABOutdoor Sconce #254813Outdoor Lantern #0409383Security Light #1048425Pendant Light #261775Chandelier #016113Semi-Flush Mount #269137Flushmount #074435Mini Flushmount #0533270Flushmount #076042Wrap Light #EU4B10208035LED Module #LSR8BCylinder LED #LDA3BAdjustable Recessed #LDRT4CRecessed Downlight #LDSQ6CSquare Downlight

If you're trying to locate documentation for your fixture, the Portfolio lighting manuals page is a good place to start for installation guides and product documentation.

If you're trying to visually match your fixture or browse older product lines, the Portfolio lighting catalog can help you identify styles and find compatible replacements.

Identifying specific internal components for older fixtures can be a challenge, especially for discontinued units. For a comprehensive breakdown of technical specifications and wiring layouts, you can refer to our Portfolio Lighting Master Model & Replacement Handbook, which catalogs over 100 specialized models in one digital guide.

Some Portfolio model searches lead to outdoor transformers and path lights, but long codes with LD, LDRT, ERM, D010TE, DE010, or trim finish segments usually belong to architectural recessed LED products. Those should be matched through the Portfolio architectural LED catalog guide before choosing a parts path.

How to Use This Directory

Repair Rule

Replace the failed part, not the entire system, when the transformer, photocell, timer, terminal lug, stake, glass, driver, socket, or connector is the actual problem.

Featured Portfolio Model Repair Pages

Some Portfolio model numbers need more than a basic lookup because the real repair depends on the fixture style, connector type, transformer behavior, socket condition, lens seal, and discontinued part compatibility.

Start with the SS9C-P5-BKT-CPK1 model guide for bundled fixture identification, the 0378225 cable connector repair page for splice and oxidation failures, the 0157561 flood light parts guide for flood fixture repair, the 0062582 path light manual page for socket and stake diagnostics, the 0805200 transformer manual for power-center testing, and the 7404280540 replacement parts guide for fixture-level compatibility.

These pages are designed to help owners diagnose the actual failed component instead of replacing the entire system unnecessarily.

Many vintage Portfolio fixtures use replacement parts that are no longer identified by modern product listings alone. Cross-referencing model numbers with original construction details often provides a more accurate way to locate compatible hardware. The Portfolio Vintage Lighting guide explains how restoration projects combine model research with physical fixture identification to locate usable replacement parts.

Search by Symptom (Start Here if Something Broke)

For specific transformer manuals and wiring setups, check the Portfolio outdoor transformer manuals. This is where I break down model-specific controls, timers, and troubleshooting steps.

If you're seeing loose wires, overheating, or intermittent power, I’ve broken down exactly what fails and how to fix it in this guide on Portfolio lighting replacement terminal blocks and transformer lugs. In my experience, this is one of the most common failure points in older systems.

Before replacing a failed part, compare how newer drivers, transformers, smart controls, and LED systems behave in the lighting hardware compatibility and performance comparison archive.

Check the Portfolio system from power source to fixtures

If the lights are out, confirm the protected supply receptacle and timer settings before checking the low-voltage cable and fixture connections. Disconnect power before opening or servicing equipment; refer line-voltage faults to a qualified electrician.

Portfolio troubleshooting Portfolio replacement parts landscape lighting electrical safety

Transformer & Power Pack

This group is organized as an action-and-repair directory. Use the model card to identify the likely replacement part, common failure point, and next troubleshooting move.

For deeper transformer diagnostics, see the Portfolio lighting transformer master guide.

For wiring diagrams and step-by-step installation details, see the Portfolio lighting technical manuals and wiring diagrams. This is especially helpful if you're troubleshooting transformers, photocells, or connection layouts.

If you’re working with models like 284369, TC001, or 284357, I’ve put together a focused breakdown with manuals and parts in this guide: Portfolio lighting models 284369, TC001, and 284357 manuals and parts.

Model 121408: 200W Transformer

If you're working with the 121408 transformer specifically, I’ve put together a full breakdown with wiring, controls, and common failure points in this Portfolio lighting model 121408 transformer manual. This is the exact process I use to diagnose and fix these units.

Transformer & Power Pack Model #121408

Quick Specs:
Input: 120V AC • Output: 12V AC (multi-tap)
Capacity: 200W • Outdoor rated metal housing
Control: Photocell compatible (EPC-1)
Common Failure Point: Terminal lugs + photocell sensor

Directory Field Action and Repair Detail Core Info A heavy-duty multi-tap outdoor transformer. The Stone to Turn Over EPC-1 photocell compatibility. Troubleshooting Target System not turning on: check GFCI, timer mode, photocell, output terminals, and internal thermal fuse behavior. Replacement Part Direction Photocell, terminal lugs, timer parts, transformer output screws, outdoor-rated connectors

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 121408? Ask our Specialist ↑ Back to Top Search

Model SL-200-12: 200W Manual Transformer

If you're using the SL-200-12 transformer and the timer isn’t working correctly or the lights won’t follow the schedule, I’ve put together a full breakdown in this Portfolio SL-200-12 troubleshooting guide. It walks through the exact timer and power checks I use to fix these units.

Transformer & Power Pack Model #SL-200-12

Quick Specs:
Input: 120V AC • Output: 12V AC
Capacity: 200W • Manual dial timer
Control: Mechanical timer pins
Common Failure Point: Timer motor + worn pins

Directory Field Action and Repair Detail Core Info Known for its mechanical timer interface. The Stone to Turn Over Timer replacement pins and manual override toggle switches. Troubleshooting Target Timer not spinning: confirm 120V input and clock motor operation before replacing the whole transformer. Replacement Part Direction Timer pins, manual override switch, terminal screws, output lugs

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model SL-200-12? Ask our Specialist ↑ Back to Top Search

Model 0312384: 120W Transformer

If you're working with the 0312384 transformer or system and need to replace a failed component, I’ve broken down the exact parts that typically fail in this Portfolio lighting model 0312384 replacement parts guide. This is where I map what usually goes bad and what actually fixes it.

Transformer & Power Pack Model #0312384

Quick Specs:
Input: 120V AC • Output: 12V AC
Capacity: 120W • Entry-level transformer
Wire Support: 12–14 AWG terminals
Common Failure Point: Voltage drop under load

Directory Field Action and Repair Detail Core Info A mid-range unit often found in starter landscape kits. The Stone to Turn Over Low-voltage terminal lug sizes, typically 12-14 AWG. Troubleshooting Target Low output: test the secondary coil for 12V vs. 11V drops under load. Replacement Part Direction Terminal lugs, output screws, photocell or timer parts, waterproof connectors

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 0312384? Ask our Specialist ↑ Back to Top Search

Model 0095115: 45W Transformer

Transformer & Power Pack Model #0095115

Quick Specs:
Input: 120V AC • Output: 12V AC
Capacity: 45W • Dusk-to-dawn photocell unit
Control: Integrated sensor
Common Failure Point: Dirty or blocked photocell

Directory Field Action and Repair Detail Core Info Entry-level dusk-to-dawn unit. The Stone to Turn Over Integrated photocell specs and sensor-eye placement. Troubleshooting Target Lights stay on 24/7: clean the sensor eye or check for shadows. Replacement Part Direction Photocell assembly if serviceable, terminal screws, small-run connectors

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 0095115? Ask our Specialist ↑ Back to Top Search

Model BT-150-12: 150W Power Pack

Transformer & Power Pack Model #BT-150-12

Quick Specs:
Input: 120V AC • Output: 12V AC
Capacity: 150W • Digital display transformer
Control: Resettable overload system
Common Failure Point: Overload trips + reset switch wear

Directory Field Action and Repair Detail Core Info Reliable 150W unit with a digital display. The Stone to Turn Over Reset button location and overload error-code meanings. Troubleshooting Target Overload: calculate total wattage on the 12V line. Replacement Part Direction Reset button, digital timer module, terminal lugs, photocell parts

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model BT-150-12? Ask our Specialist ↑ Back to Top Search

Model YL-56-12: Low Voltage Power Supply

Transformer & Power Pack Model #YL-56-12

Quick Specs:
Input: 120V AC • Output: 12V (LED driver style)
Capacity: ~56W • Compact power supply
Wiring: Polarity-sensitive output
Common Failure Point: Terminal block + polarity errors

Directory Field Action and Repair Detail Core Info Compact power supply often used for smaller LED runs. The Stone to Turn Over Input/output wiring diagram logic; polarity matters for LED. Troubleshooting Target Power loss at the terminal block: inspect loose screws, corrosion, polarity, and output voltage. Replacement Part Direction Terminal block, low-voltage leads, LED driver-compatible connectors

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model YL-56-12? Ask our Specialist ↑ Back to Top Search

Specialty Components

This group is organized as an action-and-repair directory. Use the model card to identify the likely replacement part, common failure point, and next troubleshooting move.

If you're dealing with flickering or LED issues, review the Portfolio LED lighting guide for driver and voltage troubleshooting.

A Portfolio model number identifies a product or product family, but it should not automatically be treated as the name of its manufacturer. Portfolio products were sold under a private-brand structure, so manufacturer research may require additional evidence from the manual, Lowe's item number, UL or ETL certification record, FCC ID, importer information, or internal component labels. Our Who Made Portfolio Lighting? guide shows how to combine those clues without confusing the Portfolio brand, retailer, supplier, component maker, and physical manufacturer.

Model EPC-1: Remote Photocell

Specialty Components Model #EPC-1

Quick Specs:
Voltage: 120V line voltage control
Wiring: 3-wire (Line / Neutral / Load)
Use Case: Universal transformer sensor replacement
Common Failure Point: Sensor degradation + wiring mix-up

Directory Field Action and Repair Detail Core Info Universal replacement sensor for most Portfolio transformers. The Stone to Turn Over 3-wire color coding: Black = Line, White = Neutral, Red = Load. Troubleshooting Target Lights will not turn on at dusk: clean sensor, check line/load wiring, and block sensor to test. Replacement Part Direction Photocell sensor, wire connectors, weatherproof mounting hardware

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model EPC-1? Ask our Specialist ↑ Back to Top Search

Path, Post & Wall Fixtures

This group is organized as an action-and-repair directory. Use the model card to identify the likely replacement part, common failure point, and next troubleshooting move.

Model 0688503: LED Landscape Path Light

Path, Post & Wall Fixtures Model #0688503

Quick Specs:
Voltage: 12V low voltage
Power: ~4W integrated LED
Mounting: 1/2" NPT stake thread
Common Failure Point: Connector + stake breakage

Directory Field Action and Repair Detail Core Info 12-volt, 4-watt integrated LED path light. The Stone to Turn Over Replacement stake thread size, usually 1/2-inch NPT-style. Troubleshooting Target Path light out: test voltage at fixture before replacing integrated LED head. Replacement Part Direction Stake, connector, fixture head, low-voltage splice

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 0688503? Ask our Specialist ↑ Back to Top Search

Model FS130125-7: Outdoor Wall Light

Path, Post & Wall Fixtures Model #FS130125-7

Quick Specs:
Voltage: 120V line voltage
Material: Metal housing + glass panels
Mounting: Wall junction box
Common Failure Point: Water intrusion + gasket failure

Directory Field Action and Repair Detail Core Info Outdoor wall light with replaceable glass panels. The Stone to Turn Over Glass panel dimensions for weather damage replacement. Troubleshooting Target Water entry: inspect wall box seal, gasket, glass clips, and mounting plate. Replacement Part Direction Glass panel, gasket, mounting screws, outdoor wire connectors

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model FS130125-7? Ask our Specialist ↑ Back to Top Search

Model 155153: Outdoor Lantern

Path, Post & Wall Fixtures Model #155153

Quick Specs:
Voltage: 120V
Fixture Type: Outdoor lantern
Bulb Base: Typically E26 medium base
Common Failure Point: Corrosion + socket wear

Directory Field Action and Repair Detail Core Info Outdoor lantern fixture used for entry and exterior wall lighting. The Stone to Turn Over Anti-corrosion tips for the finish and glass cleaning. Troubleshooting Target Finish corrosion: clean gently, inspect seal, and avoid harsh abrasives. Replacement Part Direction Glass, mounting screws, gasket, lamp socket parts

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 155153? Ask our Specialist ↑ Back to Top Search

Model 0012351: Post Light

Path, Post & Wall Fixtures Model #0012351

Quick Specs:
Voltage: 120V
Mounting: Standard 3" post fit
Fixture Type: Outdoor post light
Common Failure Point: Loose mount + base corrosion

Directory Field Action and Repair Detail Core Info Outdoor post light designed around standard post mounting. The Stone to Turn Over Mounting diameter: standard 3-inch post fitment. Troubleshooting Target Loose post fit: confirm post diameter, set screws, and base corrosion. Replacement Part Direction Post fitter screws, glass, socket, gasket

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 0012351? Ask our Specialist ↑ Back to Top Search

Model LD1702AB: Outdoor Sconce

Path, Post & Wall Fixtures Model #LD1702AB

Quick Specs:
Voltage: 120V
Sensor: PIR motion detection
Control: Adjustable sensitivity
Common Failure Point: Dirty lens + sensor misfire

Directory Field Action and Repair Detail Core Info Outdoor sconce with motion/PIR sensing features. The Stone to Turn Over Motion sensor sensitivity settings and PIR lens replacement. Troubleshooting Target Motion problems: clean PIR lens, adjust sensitivity, check warm-up mode, and test manual override. Replacement Part Direction PIR lens, sensor module if serviceable, mounting hardware, glass

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model LD1702AB? Ask our Specialist ↑ Back to Top Search

Model 254813: Outdoor Lantern

Path, Post & Wall Fixtures Model #254813

Quick Specs:
Voltage: 120V
Feature: Motion + manual override
Mounting: Wall box
Common Failure Point: Override mode lock + sensor failure

Directory Field Action and Repair Detail Core Info Outdoor lantern that may use candelabra or medium base depending on version. The Stone to Turn Over Identify Candelabra E12 vs. Medium E26 base requirements. Troubleshooting Target Wrong bulb fit: check socket base and maximum wattage before installing bulbs. Replacement Part Direction E12/E26 bulb, glass, gasket, mounting bracket

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 254813? Ask our Specialist ↑ Back to Top Search

Security & Interior Lighting

This group is organized as an action-and-repair directory. Use the model card to identify the likely replacement part, common failure point, and next troubleshooting move.

Model 0409383: Security Light

Security & Interior Lighting Model #0409383

Quick Specs:
Voltage: 120V
Feature: Motion + manual override
Mounting: Wall box
Common Failure Point: Override mode lock + sensor failure

Directory Field Action and Repair Detail Core Info Exterior security light with manual override behavior. The Stone to Turn Over Manual override mode controlled by wall switch sequence. Troubleshooting Target Lights stuck on: reset wall switch sequence, check sensor, and verify photocell/daylight behavior. Replacement Part Direction PIR sensor, lamp heads, wall gasket, mounting screws

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 0409383? Ask our Specialist ↑ Back to Top Search

Model 1048425: Pendant Light

Security & Interior Lighting Model #1048425

Quick Specs:
Voltage: 120V line voltage
Fixture Type: Hanging pendant light (ceiling canopy mount)
Mounting: Standard junction box with canopy + threaded rod or chain
Bulb Base: Typically E26 medium base (verify before ordering)
Glass Fit: Match fitter diameter (common sizes: 2.25" or 3.25")
Hidden Search Variations: Portfolio 1048425 pendant, Item #1048425, Portfolio pendant glass shade replacement, Portfolio hanging light canopy parts
Common Failure Point: Loose shade ring, cracked glass, missing canopy hardware, incorrect fitter size

Directory Field Action and Repair Detail Core Info Pendant fixture with glass shade and mounting ring. The Stone to Turn Over Glass shade diameter and mounting ring size. Troubleshooting Target Loose shade: confirm retaining ring, shade diameter, and socket collar fit. Replacement Part Direction Glass shade, retaining ring, canopy hardware

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 1048425? Ask our Specialist ↑ Back to Top Search

Model 261775: Chandelier

Security & Interior Lighting Model #261775

Quick Specs:
Voltage: 120V line voltage
Fixture Type: Chain-hung chandelier
Mounting: Ceiling junction box with canopy and chain support
Hidden Search Variations: Portfolio 261775 chandelier, Item #261775, Portfolio chandelier chain parts
Common Failure Point: Chain support, canopy hardware, socket wear

Directory Field Action and Repair Detail Core Info Chandelier fixture with chain-supported hanging assembly. The Stone to Turn Over Linkable chain specs and hanging weight. Troubleshooting Target Hanging issue: check chain rating, canopy support, junction box rating, and fixture weight. Replacement Part Direction Chain links, canopy, mounting strap, socket parts

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 261775? Ask our Specialist ↑ Back to Top Search

Model 016113: Semi-Flush Mount

Security & Interior Lighting Model #016113

Quick Specs:
Voltage: 120V line voltage
Fixture Type: Semi-flush ceiling light
Shade System: Diffuser or glass held by clips / retaining hardware
Hidden Search Variations: Portfolio 016113 semi flush, Item #016113, Portfolio ceiling light clips
Common Failure Point: Loose diffuser clips, heat-stressed shade hardware

Directory Field Action and Repair Detail Core Info Semi-flush mount ceiling fixture with diffuser clips. The Stone to Turn Over Diffuser clip replacement part numbers. Troubleshooting Target Loose diffuser: inspect clip tension, heat damage, and glass lip. Replacement Part Direction Diffuser clips, glass shade, mounting screws

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 016113? Ask our Specialist ↑ Back to Top Search

Model 269137: Flushmount

Security & Interior Lighting Model #269137

Quick Specs:
Voltage: 120V line voltage
Fixture Type: Flushmount ceiling light (low-profile mount)
Mounting: Direct to junction box with center mounting plate
Bulb Base: Typically E26 medium base (enclosed fixture rated)
Glass Style: Twist-lock or finial-mounted diffuser (varies by revision)
Hidden Search Variations: Portfolio 269137 flushmount, Item #269137, Portfolio ceiling light glass replacement, Portfolio flush mount diffuser stuck
Common Failure Point: Stuck glass dome, over-tightened finial, heat expansion locking diffuser, socket wear from high wattage bulbs

Directory Field Action and Repair Detail Core Info Flushmount ceiling fixture with socket wattage limits. The Stone to Turn Over Maximum wattage per socket to avoid melted insulation. Troubleshooting Target Heat damage: check bulb wattage, socket condition, and insulation discoloration. Replacement Part Direction Socket, glass, mounting screws, approved bulb

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 269137? Ask our Specialist ↑ Back to Top Search

Model 074435: Mini Flushmount

Security & Interior Lighting Model #074435

Quick Specs:
Voltage: 120V line voltage
Fixture Type: Mini flushmount ceiling light
Best Use: Small rooms, closet-style spaces, pantry-style areas
Hidden Search Variations: Portfolio 074435 mini flushmount, Item #074435, small Portfolio ceiling light
Common Failure Point: Heat buildup, tight clearance, wrong bulb wattage

Directory Field Action and Repair Detail Core Info Compact flushmount useful for closet or pantry spaces. The Stone to Turn Over Closet/pantry clearance code concerns. Troubleshooting Target Overheating: use correct bulb wattage and observe fixture clearance requirements. Replacement Part Direction Glass, socket, mounting screws

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 074435? Ask our Specialist ↑ Back to Top Search

Model 0533270: Flushmount

Security & Interior Lighting Model #0533270

Quick Specs:
Voltage: 120V line voltage
Fixture Type: Flushmount ceiling light
Glass Style: Twist-lock or clip-retained shade depending on version
Hidden Search Variations: Portfolio 0533270 flushmount, Item #0533270, stuck Portfolio glass shade
Common Failure Point: Stuck glass, heat expansion, clip tension loss

Directory Field Action and Repair Detail Core Info Flushmount fixture with twist-and-lock glass. The Stone to Turn Over Twist-and-lock glass removal instructions, often stuck by heat. Troubleshooting Target Stuck glass: let cool completely, support glass, and rotate carefully without forcing clips. Replacement Part Direction Glass shade, clips, socket parts

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 0533270? Ask our Specialist ↑ Back to Top Search

Model 076042: Wrap Light

Security & Interior Lighting Model #076042

Quick Specs:
Voltage: 120V line voltage
Fixture Type: Utility wrap light / garage light
Lens Type: Long acrylic diffuser
Hidden Search Variations: Portfolio 076042 wrap light, Item #076042, Portfolio wrap light lens replacement
Common Failure Point: Yellowed diffuser, cracked lens, ballast or driver failure

Directory Field Action and Repair Detail Core Info Wrap light fixture with acrylic lens. The Stone to Turn Over Acrylic lens replacement and ballast bypass instructions for LED. Troubleshooting Target Flicker or no start: check ballast, tombstones, and LED tube compatibility. Replacement Part Direction Acrylic lens, ballast, LED tubes, tombstones

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model 076042? Ask our Specialist ↑ Back to Top Search

Recessed & Commercial LED

This group is organized as an action-and-repair directory. Use the model card to identify the likely replacement part, common failure point, and next troubleshooting move.

Model EU4B10208035: LED Module

Recessed & Commercial LED Model #EU4B10208035

Quick Specs:
Type: LED replacement module / integrated LED component
Power Type: Driver-controlled LED output
Match By: Output voltage, current, connector, module size, and mounting holes
Hidden Search Variations: Portfolio EU4B10208035 LED module, LED driver board, Portfolio LED replacement module
Common Failure Point: Driver mismatch, dim output, flicker, failed LED board

Directory Field Action and Repair Detail Core Info LED module with 3500K color temperature and driver input requirements. The Stone to Turn Over Color temperature 3500K and driver input voltage. Troubleshooting Target Module dead: test driver input/output before replacing LED module. Replacement Part Direction LED module, driver, spring clips, connector

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model EU4B10208035? Ask our Specialist ↑ Back to Top Search

Model LSR8B: Cylinder LED

Recessed & Commercial LED Model #LSR8B

Quick Specs:
Voltage: 120V line voltage or driver-fed LED depending on fixture version
Fixture Type: Cylinder LED downlight / surface-style fixture
Match By: Trim size, driver rating, color temperature, and mounting method
Hidden Search Variations: Portfolio LSR8B cylinder LED, LSR8B light, Portfolio cylinder downlight
Common Failure Point: Driver failure, color shift, trim mismatch

Directory Field Action and Repair Detail Core Info Cylinder LED fixture for commercial or architectural applications. The Stone to Turn Over Mounting bracket for commercial junction boxes. Troubleshooting Target Mounting problem: confirm box type, bracket hole pattern, and fixture weight. Replacement Part Direction Mounting bracket, driver, trim, junction box hardware

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model LSR8B? Ask our Specialist ↑ Back to Top Search

Model LDA3B: Adjustable Recessed

Recessed & Commercial LED Model #LDA3B

Quick Specs:
Fixture Type: Adjustable recessed LED / directional downlight
Match By: Aperture size, trim style, driver output, and swivel range
Hidden Search Variations: Portfolio LDA3B recessed light, LDA3B adjustable downlight, Portfolio directional recessed LED
Common Failure Point: Driver flicker, loose trim springs, aiming mechanism wear

Directory Field Action and Repair Detail Core Info Adjustable recessed fixture with gimbal aiming. The Stone to Turn Over Gimbal tilt angle, commonly a 30-degree range, and trim compatibility. Troubleshooting Target Aiming issue: verify trim clearance and gimbal movement before forcing adjustment. Replacement Part Direction Trim, spring clips, driver, LED module

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model LDA3B? Ask our Specialist ↑ Back to Top Search

Model LDRT4C: Recessed Downlight

Recessed & Commercial LED Model #LDRT4C

Quick Specs:
Fixture Type: 4-inch recessed LED downlight / retrofit-style trim
Match By: Can size, trim diameter, connector type, and color temperature
Hidden Search Variations: Portfolio LDRT4C recessed light, LDRT4C downlight, Portfolio 4 inch LED trim
Common Failure Point: Weak spring clips, driver flicker, wrong can fit

Directory Field Action and Repair Detail Core Info 4-inch recessed downlight style fixture. The Stone to Turn Over Spring clip replacement for loose housings. Troubleshooting Target Fixture sagging: inspect clip tension, ceiling thickness, and housing fit. Replacement Part Direction Spring clips, trim, driver, connector

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

Have a different issue with Model LDRT4C? Ask our Specialist ↑ Back to Top Search

Model LDSQ6C: Square Downlight

Recessed & Commercial LED Model #LDSQ6C

Quick Specs:
Fixture Type: 6-inch square recessed LED downlight
Match By: Square trim size, can compatibility, driver output, and Kelvin rating
Hidden Search Variations: Portfolio LDSQ6C square downlight, LDSQ6C LED trim, Portfolio square recessed light
Common Failure Point: Trim fit, driver failure, color mismatch

Directory Field Action and Repair Detail Core Info Square recessed downlight style fixture. The Stone to Turn Over Square-to-round junction box adapter requirements. Troubleshooting Target Poor fit: confirm adapter ring, box shape, trim size, and spring clip alignment. Replacement Part Direction Adapter, trim, spring clips, driver

Before ordering: Match the model number, voltage, mounting method, finish, dimensions, and connector style. If your label is faded, use the Portfolio lighting model number lookup.

If you're seeing newer replacements or different branding, review the Portfolio to Origin21 rebrand guide to understand compatibility and what parts will still work with your system.

When exact replacement parts cannot be found, cross-compatibility becomes more important than model matching. The legacy landscape lighting parts compatibility guide explains which older components commonly interchange across discontinued systems.

Have a different issue with Model LDSQ6C? Ask our Specialist ↑ Back to Top Search

Recently Added Portfolio Fixture Model Guides

Identifying discontinued Portfolio fixtures and sourcing replacement parts is much harder when no documentation exists online. The model-specific guides below cover the most-searched discontinued Portfolio fixture item numbers — each page provides specs, parts identification, troubleshooting by symptom, and compatible replacement options for that specific model.

If you are working with outdoor wall lanterns, deck lights, or fixtures with internal circuit boards that have no available manual, these pages are the most complete resources available. Each guide also links to the broader Portfolio replacement parts library, the model number lookup, and the discontinued Portfolio lighting hub.

If a Portfolio model does not appear in a normal parts directory, it may still be identifiable by its number pattern, finish code, voltage, fixture shape, or failure behavior. The Portfolio Lighting Lost Models Archive is designed for these uncertain cases, especially models where the correct part depends on comparing the label, bulb access, lens style, stake thread, socket type, or transformer connection method.

Plan repairs without losing the original Portfolio layout

Record the existing transformer terminals, cable runs, fixture count, and lamp ratings before upgrading. Check output compatibility and total connected load when considering LED conversion or a different transformer.

Portfolio LED conversion Portfolio landscape lighting Portfolio model lookup

📋 New Fixture Model Pages — Parts, Troubleshooting & Replacement

Dedicated guides for five discontinued Portfolio fixture models — the most specific and actionable resources available for these item numbers anywhere online.

Low-Voltage Deck Light

Portfolio Model 0094007 Deck Light Parts Guide

Connector failure identification, LED module replacement, compatible deck light alternatives, and parts sourcing for this discontinued low-voltage deck fixture.

Outdoor Wall Lantern

Portfolio Model 0253849 Parts and Manual

Mounting hardware sourcing, globe replacement strategy, fixture identification without a model label, and compatible current-production replacements.

Outdoor Wall Lantern

Portfolio Model 0140792 Globe Replacement Guide

Globe dimension identification, aftermarket globe sourcing when manufacturer stock is gone, and compatible replacement fixture options for this lantern set.

Known Design Defect

Portfolio Model 4440AR Parts and Fix Guide

Documents the confirmed bottom-cap separation defect, available fix options, and the most compatible replacement fixtures when the original cannot be repaired.

Internal Circuit Board

Portfolio Model 230305 Circuit Board Troubleshooting

Circuit board identification methodology, driver board fault diagnosis, generic replacement board sourcing, and full symptom-to-cause troubleshooting table for this undocumented model.

For the full list of discontinued Portfolio model guides including transformer-specific pages, use the discontinued Portfolio lighting hub or the model number lookup to find the guide that matches your specific item number.

Why Portfolio Model Directories Matter for Real Repairs

A true Portfolio Lighting parts directory should do more than list model numbers. The real challenge with older Portfolio fixtures is identifying whether the failed component is actually the lens, shade, connector, transformer, stake, LED module or mounting hardware. Many discontinued Portfolio fixtures share similar housings while using completely different internal parts and electrical layouts.

The 016107 WHCM432R8 lens and parts guide explains how gasket compression, retainer depth and lens geometry affect replacement compatibility, while the 0311569 kit replacement guide demonstrates why older Portfolio fixture kits can create confusion when homeowners search for one failed component instead of the complete assembly.

Hardware compatibility also becomes increasingly important as Portfolio fixtures age. The 17945-000 shade replacement guide focuses heavily on fitter sizing, diffuser stability and shade-retention issues, while the 230132-145P replacement guide explains how intermittent low-voltage connector failures are often mistaken for total fixture failure.

Many discontinued models also require rebuilding missing manual information from field evidence. The FY09-003 0048184 manual guide, 18907-000 repair guide, 25966-3 troubleshooting guide and 2851294 replacement guide all show how transformer labels, bulb markings, connector styles and fixture geometry can reconstruct missing installation and compatibility data that no longer exists online.

Newly documented exact-model service records

These additions were selected because surviving manuals or archived product records preserve model-specific parts, dimensions, lamp requirements or mounting details. Each link below is paired with the technical clue that makes the record useful; this is not a general related-links list.

Portfolio Lighting Model Parts Directory FAQ

What is the Portfolio Lighting Model Parts Directory?

It is an action-and-repair hub that connects Portfolio model numbers to common failure points, likely replacement parts, and next troubleshooting steps.

How do I find the right replacement part for a Portfolio model?

Start by matching the model number, product category, voltage, fixture dimensions, connector style, and known failure point. Then use the model card to identify likely replacement parts such as photocells, terminal lugs, stakes, glass, drivers, or mounting hardware.

Should I replace the whole Portfolio fixture or only the part?

If the transformer, connector, stake, glass, socket, driver, or sensor is the only failed item, a part replacement may be enough. If an integrated LED fixture is sealed, water-damaged, or non-serviceable, full fixture replacement may be the better repair path.

What if my model number is not listed?

Use the closest product category and compare voltage, dimensions, connector style, finish, and failure symptoms. You can also use the contact page to send the model and issue so the directory can be improved over time.

If you can’t find your exact part, don’t guess—use this Portfolio lighting alternatives guide to find compatible replacements that actually work with your system.

Related Portfolio Model, Manual and Repair Guides

Philip Meyer - Lighting Expert

Reviewed by Philip Meyer

Lighting Specialist • Model Parts • Transformer and Fixture Repair

Philip Meyer focuses on practical Portfolio lighting diagnostics: model number identification, transformer parts, photocells, terminal lugs, timer resets, replacement stakes, glass panels, LED drivers, security lights, recessed modules, and the repair decisions homeowners face when a single part fails.