Home › Portfolio Model Parts Directory › LWS1204B3

📦Shop Portfolio-Compatible Lighting Parts on AmazonAffiliate link · We may earn a commission.🔧Find Discontinued Portfolio Parts on eBayAffiliate link · We may earn a commission.

Outdoor Wall Lantern • 9594KIT Hardware Documented

Portfolio LWS1204B3 / 0617810 Wall Lantern Parts & Repair Guide

Portfolio LWS1204B3, item 0617810, has unusually actionable surviving documentation for an outdoor lantern. The manual identifies the crossbar assembly, fixture loop and fixture body, and its replacement-parts section groups the wire connectors, outlet-box screws and crossbar assembly under part 9594KIT. It also gives a sealing detail that is easy to miss: seal the top and sides of the backplate, but leave the bottom unsealed so moisture can drain.

ModelLWS1204B3

Lowe’s item0617810

FixtureWall lantern

Hardware kit9594KIT

What 9594KIT actually covers

The replacement-parts list associates 9594KIT with the wire connector, outlet-box screw and crossbar assembly. That does not mean every modern kit sold under a similar description is automatically interchangeable. Compare bracket width, hole spacing, screw thread and the fixture’s mounting-screw positions. For wire connectors, use currently listed connectors sized for the actual conductor combination.

The backplate sealing instruction is a diagnostic clue

The manual instructs installers to apply exterior sealant across the top of the backplate and down both sides while not sealing the bottom. The open bottom provides a drainage path. If an older LWS1204B3 shows corrosion or water staining, inspect whether previous caulk work trapped moisture by sealing all four sides, as well as whether the wall surface or box opening allows water behind the fixture.

Crossbar assembly versus fixture-body failure

A lantern that rocks against the wall, hangs crooked or will not pull tight is usually a mounting-path problem first. Inspect the outlet box, crossbar, mounting screws and backplate alignment. Cracked decorative metal or a damaged fixture loop is a separate mechanical problem. Keeping those diagnoses separate prevents replacement of a serviceable fixture body for a loose bracket.

Wiring sequence and grounding

The manual shows conventional black/hot, white/neutral and grounding connections through the outlet box. If the lantern is completely dead, verify supply and connections with power handled safely before blaming the lamp socket. If insulation is heat-damaged or corrosion has migrated into conductors, the repair has moved beyond cosmetic hardware and should be evaluated accordingly.

Outdoor moisture changes the replacement decision

On an exterior wall lantern, a new socket or connector will not last if the moisture path remains. Look for failed top/side sealant, an uneven mounting surface, water entry from above and corrosion around the box. After correcting the source, preserve the bottom drainage opening described by the manual. The Portfolio outdoor-lighting pillar provides broader weatherproofing context.

How to shop for a discontinued LWS1204B3 part

Start with the exact model and item number, then use 9594KIT as an original-reference clue for the mounting hardware. For substitute brackets or screws, match measurements. For glass or decorative pieces not assigned an original part number in the surviving replacement list, measure the physical fixture rather than borrowing dimensions from another LWS1204-family lantern. Use the model parts directory to compare documented relatives without assuming interchangeability.

Reconstruct the original mounting path before buying hardware

The manual’s crossbar assembly attaches to the outlet box, and preassembled mounting screws project outward to receive the fixture. That means a replacement bracket has to satisfy two geometries at once: it must attach correctly to the box and place the fixture-mounting screws where the backplate expects them. Measure center-to-center spacing and screw projection on the original assembly before substituting a generic crossbar.

If the backplate sits proud of the wall, do not automatically shorten screws. First confirm that conductors are folded into the box without being pinched and that the crossbar is oriented correctly. Excessive screw projection, a reversed bracket or an uneven wall surface can produce similar symptoms.

Why the unsealed bottom edge matters

Exterior caulk is often applied with the instinct that “more sealed is better.” LWS1204B3’s manual provides a more specific strategy: seal across the top and down the sides, leaving the bottom unsealed. That creates a path for incidental moisture to escape. A fixture that was later caulked completely around the perimeter can trap water behind the backplate. When correcting that condition, also inspect the outlet-box opening and siding/masonry interface; drainage at the fixture cannot compensate for water continuously entering from above.

LWS1204B3 moisture and mounting symptom map

SymptomInspectModel-specific clueRust at bottom of backplateDrainage opening and water source aboveThe manual expects the bottom edge to remain unsealed.Backplate rocks9594KIT crossbar geometry and outlet boxThe crossbar is a documented replaceable hardware component.Fixture dead after rainMoisture path plus electrical connectionsCorrect water entry before replacing connectors or socket parts.Mounting screw missingOriginal screw thread/spacingDo not assume every universal crossbar screw fits the fixture side.Corroded wire connectorConductor condition inside box9594KIT historically included connectors, but modern replacements should be listed for the actual conductors.

What 9594KIT does not establish

9594KIT is an original reference for the wire connector, outlet-box screw and crossbar assembly listed in the manual. It does not establish that glass, socket parts, decorative loops or other LWS1204-family components are interchangeable. It also does not mean an unverified online “9594KIT equivalent” matches the original bracket geometry. Treat the number as a research key, then verify the physical part.

The model suffix matters too. LWS1204B3 should not automatically inherit dimensions from LWS1204B, LWS1204C or another family member merely because the prefix is similar. Family resemblance is useful for research; it is not a fit guarantee.

Where this exact model fits in the Portfolio archive

This page stays narrow: it documents LWS1204B3 rather than trying to become another sitewide directory. Use these broader resources only when the repair question moves beyond this exact fixture.

Master Model Technical Database

Use the database to cross-reference another Portfolio model or item number. It is the comprehensive model index, while this page remains specific to LWS1204B3.

Model Parts Directory

Use the parts directory when the failed component may appear across multiple Portfolio products and you need a broader parts-oriented route.

LWS1204B3 FAQ

What replacement hardware number is documented for LWS1204B3?

The manual lists 9594KIT for the wire connector, outlet-box screw and crossbar assembly.

Should I caulk all four sides of the backplate?

No. The manual says to seal the top and sides but not the bottom, so moisture can drain.

What is the item number for LWS1204B3?

The surviving manual identifies Lowe’s item 0617810.

Research standard for this model

This guide separates facts documented for the exact model from measurements or compatibility checks that still have to be made on the installed fixture. It does not assume that a visually similar Portfolio product shares glass, brackets, sockets or electrical parts.

Source basis: Portfolio LWS1204B3 wall-lantern manual, item 0617810, dated in the manual 2015-01-12. Page research updated October 6, 2026.

Editorial review: Philip Meyer. For broader methodology and site ownership information, see About PortfolioLighting.net.