Home › Portfolio Model Parts Directory › FD12-001
📦Shop Portfolio-Compatible Lighting Parts on AmazonAffiliate link · We may earn a commission.🔧Find Discontinued Portfolio Parts on eBayAffiliate link · We may earn a commission.
Discontinued Hanging Lantern • Exact Model Research
Portfolio FD12-001 / 0356745 Hanging Lantern Parts & Repair Guide
The surviving Portfolio manual identifies FD12-001 as item 0356745, a hanging lantern. More importantly for an owner trying to save the fixture, the package diagram separates the decorative assembly into a cover, two decorative nuts, four small glass pieces, four large glass pieces, a hex nut and finial. That component map is far more useful than treating the lantern as one replace-or-discard object.
ModelFD12-001
Lowe’s item0356745
FixtureHanging lantern
Manual codeEB14537
What the original package diagram establishes
The manual names eight visible fixture components: decoration, cover, decorative nuts, fixture body, four small glass panels, four large glass panels, hex nut and finial. That means a broken glass panel, missing finial or loose decorative nut is a mechanical parts problem first—not evidence that the entire lantern is electrically failed. Keep the original hardware until measurements are recorded because decorative lantern parts are commonly shape- and thread-dependent.
Glass replacement: measure the panel, not the lantern
FD12-001 uses separate small and large glass pieces. Before ordering glass, remove only a safely accessible intact panel and record its height, width, thickness, edge shape and whether it slides into a channel or is retained by tabs. Do not order from an overall lantern dimension. A replacement can match the lantern’s visual style and still fail to fit the panel opening. The site’s Portfolio replacement-glass guide explains how to measure openings and retained panels before buying.
Finial, cover and decorative-nut diagnosis
The manual shows the cover preassembled to the fixture and the decorative nuts preassembled to the cover. The finial is paired with a hex nut. If the lantern rattles, hangs crooked or has a loose top assembly, inspect these mechanical interfaces before disturbing the branch-circuit wiring. Photograph the order of washers, nuts and decorative pieces during disassembly; the sequence matters when a threaded stem has limited engagement.
Mounting and wiring evidence from the manual
The hardware list includes three wire nuts and two mounting screws, confirming a conventional hardwired installation rather than a plug-in or low-voltage landscape connection. When replacing mounting hardware, match screw diameter, thread pitch, usable length and bracket geometry. For wiring faults, power should be disconnected at the breaker and the supply, neutral and grounding connections verified rather than assuming the socket or lamp is the first failure.
A better troubleshooting order for FD12-001
If the lantern is dark, first confirm the lamp and power supply, then inspect the switch/control and wiring connections. If only one physical area is damaged—glass, finial, cover or decorative hardware—treat that as a separate repair path. If moisture is present, locate the entry path before installing new electrical components. The Portfolio outdoor-lighting pillar provides the broader weather-exposure and wall/ceiling-fixture context.
Replacement decision: preserve what is still serviceable
For a discontinued decorative fixture, the most defensible replacement search starts with the failed component. Glass requires panel measurements; mounting hardware requires thread and bracket measurements; electrical components require ratings printed on the socket or fixture label. Avoid listings that claim broad Portfolio compatibility without dimensions. The model parts directory is the right next stop when comparing other documented Portfolio hardware families.
FD12-001 component-by-component inspection
Start with the lantern hanging in its normal position and photograph all four sides before disassembly. Compare the four small and four large glass pieces for differences in gap, tilt, chipped corners and retained-edge depth. If one panel sits lower than the others, the problem may be a bent retaining channel or distorted frame rather than the glass itself. Inspect the cover for deformation around the decorative nuts and look at the finial from directly below; an off-center finial can indicate a bent threaded connection.
Next, with power safely disconnected, check whether the fixture body can rotate relative to the cover. Movement there points toward loose mechanical hardware above the visible glass assembly. Keep the original hex nut and finial together in a labeled bag if removed. Decorative hardware is easy to lose and often harder to replace accurately than standard electrical hardware.
What to measure if glass is broken
For each surviving panel, record width at the top, width at the bottom, vertical height, thickness and whether the corners are square, clipped or radiused. Photograph the panel beside a ruler. Then measure the actual frame opening separately. The difference between panel size and opening size reveals how much edge engagement the lantern was designed to provide. If the small and large panels are trapezoidal, do not reduce the record to a single width measurement.
Also document whether the glass is clear, seeded, beveled, textured or tinted. A mechanically fitting replacement can still change glare and appearance if the optical treatment is different. For a single broken panel, matching the surviving seven pieces is usually a better preservation strategy than replacing all glass based on a generic lantern kit.
FD12-001 symptom-to-action map
Observed problemInspect firstWhyOne glass panel rattlesPanel seating and frame retentionThe manual shows multiple independent glass pieces, so a local fit problem does not implicate the fixture wiring.Top cover movesDecorative nuts and cover attachmentThe decorative nuts are preassembled to the cover and are part of that mechanical stack.Finial missing or looseFinial and hex-nut threadThe manual pairs those components; thread measurement is more useful than visual matching.Entire lantern darkLamp, supply, switch and wire connectionsA whole-fixture outage should be electrically isolated before decorative parts are disturbed.Corrosion near topCanopy/cover water pathWater can migrate into electrical areas even when the visible failure appears cosmetic.
What this manual does not prove
The surviving package pages identify the physical component names and quantities, but they do not by themselves establish that a glass panel or finial from another Portfolio lantern will fit FD12-001. They also do not justify copying socket ratings from a similar-looking lantern. Treat the exact fixture label and socket markings as the authority for electrical replacement work. That distinction is especially important with discontinued products, where online listings often group visually similar lanterns under one compatibility claim.
Where this exact model fits in the Portfolio archive
This page stays narrow: it documents FD12-001 rather than trying to become another sitewide directory. Use these broader resources only when the repair question moves beyond this exact fixture.
Master Model Technical Database
Use the database to cross-reference another Portfolio model or item number. It is the comprehensive model index, while this page remains specific to FD12-001.
Model Parts Directory
Use the parts directory when the failed component may appear across multiple Portfolio products and you need a broader parts-oriented route.
FD12-001 FAQ
What model and item number is this lantern?
The surviving manual identifies model FD12-001 and Lowe’s item 0356745.
Does FD12-001 use one piece of glass?
No. The package contents identify four small glass pieces and four large glass pieces, so replacement should be based on the individual panel dimensions and retention method.
Can I replace a missing finial without replacing the lantern?
Potentially, but the original finial and hex-nut thread dimensions must be measured. A decorative finial that looks similar is not proof of thread compatibility.
Research standard for this model
This guide separates facts documented for the exact model from measurements or compatibility checks that still have to be made on the installed fixture. It does not assume that a visually similar Portfolio product shares glass, brackets, sockets or electrical parts.
Source basis: Surviving Portfolio/Lowe’s FD12-001 manual, item 0356745. Page research updated October 6, 2026.
Editorial review: Philip Meyer. For broader methodology and site ownership information, see About PortfolioLighting.net.