First: 0613204 and LST04MT identify the same product
The surviving Portfolio instructions identify ITEM #0613204 and MODEL #LST04MT on the same manual cover. Lowe’s archived product data describes the Barada set as two table lamps plus a console/entryway table with a bronze finish, marble-look details and fabric shades. That matters because searching only 0613204 can make the product look like an item number with no model, while searching only LST04MT can hide retailer records. For parts research, keep both identifiers in your notes and photographs.
What the original manual actually documents
The manual’s package list includes the fabric shade, harp, side support, switch assembly, tube, base, table top, legs/support hardware, screws, Allen wrench and bottom finial. The replacement-parts list uses 613204-prefixed identifiers for several pieces, including 613204-A for the fabric shade, 613204-B for the finial, 613204-C for the harp, 613204-D for the side support, 613204-F for the tube, 613204-H for the table top, 613204-I for the leg, 613204-J for the support and 613204-AA for the screw. Those historical numbers are valuable search evidence even when original stock is gone.
Lamp will not turn on: isolate the simple causes first
If one lamp is dark, swap in a known-good bulb that matches the socket and fixture labeling before assuming the switch or socket failed. Confirm the plug is fully seated and test the receptacle with another device. If both lamps are dark, the odds of two independent lamp failures at exactly the same moment are lower, so inspect the shared room circuit or power-strip/GFCI condition first. If only one lamp fails while its mate works from the same receptacle, focus on that lamp’s bulb, switch, cord and socket path.
The switch assembly and cord deserve careful inspection
The assembly instructions route the cord through the tube/base area and specifically warn against tangling or pinching it during assembly. That warning becomes useful diagnostic evidence years later. If the lamp cuts out when the stem is moved, inspect the cord path for crushing, abrasion or strain. A damaged line-voltage cord or switch is not a cosmetic defect. Unplug the lamp before inspection, and replace unsafe electrical components with properly rated parts rather than taping over damaged insulation.
Shade, harp and finial problems are usually repairable
A missing shade or bent harp does not normally justify discarding the whole set. Measure the harp height, shade fitter style, shade diameter/height and finial thread before buying a substitute. The original manual’s 613204-A/B/C identifiers give you a starting point, but dimensions are more useful than an old part number when original service stock has disappeared. Matching both lamps matters visually; if one original shade is damaged, replacing the pair can produce a better result than chasing a single aged fabric shade.
Loose or wobbly table: diagnose the furniture separately from the lamps
Because LST04MT combines furniture and lighting, a wobble is not an electrical symptom. Put the table on a flat surface, unload it, and check the leg/support fasteners and the original screw locations. The manual calls for the legs to be oriented correctly and the screws to be started by hand before tightening with the Allen wrench. If a threaded insert spins or wood/composite material is damaged, simply tightening harder can make the repair worse. Identify whether the looseness is a fastener, insert or structural-material problem.
What to measure before substituting hardware
For a missing screw, finial, harp or support part, do not order by photograph alone. Record thread diameter and pitch where possible, screw length, head style, harp height, shade fitter dimensions and the exact location of the missing piece. Furniture hardware that is too long can break through a finished surface; lamp hardware with the wrong thread can damage a socket cap or finial stud. The historical 613204 part family helps identify intent, but physical measurement confirms fit.
When a generic replacement part makes sense
Generic lamp parts can be reasonable when the original piece is a standard mechanical component and the replacement matches the electrical rating, dimensions and mounting method. Shades, harps and finials are often easier to substitute than a proprietary decorative support or table component. For switches, sockets and cords, electrical rating and safe strain relief matter more than appearance. If you are not comfortable working on line-voltage lamp wiring, use a lamp-repair shop or qualified electrician.
Do not create a second page for “LST04MT track lighting”
Despite the requested filename wording that sometimes appears in search lists, LST04MT is documented as a console table with lamp set, not a track-lighting bar. Creating a separate “track lighting” article for this identifier would duplicate the product and introduce incorrect intent. This page therefore treats 0613204 and LST04MT as one product record and preserves the documented product type.
Replacement planning when the original set cannot be repaired
If the table structure is badly damaged or a lamp has unsafe electrical damage that cannot be economically repaired, record the console dimensions, lamp height, shade proportions, number of lamps, finish and socket/bulb requirements before shopping. A replacement does not have to carry the Portfolio name to preserve the room’s function. The useful specification is what the old set actually did in the space.
Related Portfolio research
For broader research, use the Portfolio model-number lookup, model parts directory, manuals library, and troubleshooting hub. Those pages help separate an exact-model problem from a system problem and keep replacement research tied to the label on the product rather than to appearance alone. For indoor Portfolio products, also use the indoor lighting library and lost-model archive.
A practical bench test for a lamp that cuts in and out
With the lamp unplugged, begin by documenting exactly when the interruption occurs. Does the lamp fail only when the rotary or inline switch is touched, when the stem is moved, or after it has been on long enough to warm up? Those three patterns point in different directions. A movement-sensitive failure makes the cord path and internal connections more suspicious; a switch-sensitive failure makes the switch assembly more suspicious; a heat-sensitive failure deserves inspection of the socket, bulb contact and wiring. Do not perform a live continuity test on household voltage unless you are qualified. A lamp-repair shop can test the unplugged cord, switch and socket as separate components and often preserve the original decorative body.
How to buy a replacement without losing the function of the set
If the original lamp or table cannot be saved, take measurements before disposal: table width, depth and height; lamp height from base to finial; shade bottom/top diameters and height; distance between the two lamp positions; cord exit location; and the clearance around the table. Photograph the bronze finish and marble-look surfaces in daylight. These details let you reproduce the proportions that made the set work in an entryway. Searching only for “Portfolio 0613204 replacement” may lead to scarce used inventory; searching by the actual dimensions and function opens far more practical replacement choices.