Confirmed model facts before you start

The manual identifies item 0398487 as PL126BK and item 0398489 as PL126WW.

The product record describes a wet-rated hardwired post light using one medium-base E26 lamp and a 3-inch mounting diameter.

The manual shows a fixture, fixture cover, two spacers, shade, wire connector, mounting screws, decorative nuts and fixture screws.

Before ordering anything, compare the label and physical dimensions with the Portfolio model lookup, model parts directory and parts hub.

The 3-inch post interface is the first measurement

Before replacing PL126BK, verify the actual post and the lantern base. The archived product record lists a 3-inch mounting diameter, but field posts can be painted, sleeved or deformed. Measure in several directions. A replacement that is nominally correct but binds on paint or sits loosely can become unstable in wind. Correct the post rather than forcing the lantern base.

Field note: Work from the symptom toward the failed component. Record what changes after each test instead of replacing several parts at once. That preserves the evidence you need to tell a fixture fault from a wiring, mounting, charging or control problem on 0398487 / PL126BK.

Use the E26 socket to simplify diagnosis

Because the lantern uses a conventional medium-base lamp, the bulb is easy to eliminate as a variable. Install a known-good bulb within the fixture rating. If it still fails, the problem is not the lamp. With power off, inspect the socket contact, socket shell, wire connectors and conductors entering the post. This is more efficient than replacing the entire lantern first.

Field note: Work from the symptom toward the failed component. Record what changes after each test instead of replacing several parts at once. That preserves the evidence you need to tell a fixture fault from a wiring, mounting, charging or control problem on 0398487 / PL126BK.

Wet-rated does not mean waterproof inside

A wet-location rating assumes correct assembly and installation. It does not make a cracked shade, missing cover or loose base harmless. Inspect for droplets, rust tracks and mineral deposits. Water entering from the top can travel down conductors or collect at the socket. After correcting the source, allow the fixture to dry fully before energizing it.

Field note: Work from the symptom toward the failed component. Record what changes after each test instead of replacing several parts at once. That preserves the evidence you need to tell a fixture fault from a wiring, mounting, charging or control problem on 0398487 / PL126BK.

Spacers and fixture screws matter

The manual identifies spacers and multiple fixture screws as distinct parts. If the lantern rattles, leans or the cover no longer seats, inventory those pieces rather than substituting random hardware. Wrong screw length can bottom out before clamping the fixture; oversized hardware can split plastic bosses. Save one original screw as a thread and length reference whenever possible.

Field note: Work from the symptom toward the failed component. Record what changes after each test instead of replacing several parts at once. That preserves the evidence you need to tell a fixture fault from a wiring, mounting, charging or control problem on 0398487 / PL126BK.

Black and white sibling parts

PL126BK and PL126WW share a manual family, which makes the white sibling useful for understanding assembly. That does not automatically make every visible replacement part interchangeable. Finish, material revisions and production changes can differ. Use the sibling model as a diagram reference, then confirm dimensions and attachment points on the actual black fixture before buying donor parts.

Field note: Work from the symptom toward the failed component. Record what changes after each test instead of replacing several parts at once. That preserves the evidence you need to tell a fixture fault from a wiring, mounting, charging or control problem on 0398487 / PL126BK.

When to retire PL126BK

Replace the lantern if the post-mount base is cracked, the socket is heat-damaged, conductors are brittle, water damage has reached splices, or the cover/shade can no longer be secured. If the electrical parts remain sound and only a cosmetic cover or screw is missing, a measured repair may be reasonable. The dividing line is whether the repaired fixture can remain mechanically secure and weather resistant.

Field note: Work from the symptom toward the failed component. Record what changes after each test instead of replacing several parts at once. That preserves the evidence you need to tell a fixture fault from a wiring, mounting, charging or control problem on 0398487 / PL126BK.

Symptom-to-fix table

Completely deadConfirm source power or solar charge, then test the simplest serviceable component before opening the housing.IntermittentLook for loose contacts, corrosion, moisture, weak battery or wiring that changes when the fixture moves.Dim outputCheck lamp/battery condition, dirty optical surfaces, voltage/charge availability and heat or corrosion at contacts.Water insideDisconnect power where applicable, dry the fixture, identify the entry path and replace damaged electrical parts before reuse.Broken mountingMeasure original geometry and hardware; do not let improvised mounting create a falling-fixture or water-entry hazard.

This record is especially valuable when factory replacement parts are discontinued because it lets you compare a modern substitute by function and dimensions instead of by appearance alone.

How to document a discontinued Portfolio fixture

LabelPhotograph the full model/item number before cleaning the label.ElectricalRecord voltage, bulb/battery type and any wattage or chemistry markings.MechanicalMeasure mounting diameter, backplate/post fit, screw spacing and visible part dimensions.ConditionPhotograph corrosion, cracks, water tracks and heat discoloration before disassembly.ReplacementKeep the original until the new part is installed so you can compare fit directly.

This record is especially valuable when factory replacement parts are discontinued because it lets you compare a modern substitute by function and dimensions instead of by appearance alone.

Related Portfolio repair resources

Continue with Portfolio troubleshooting, replacement parts, manuals, discontinued Portfolio lighting and the technical archive.

A quick post-lantern test before buying anything

With the breaker off, verify that the lantern is mechanically secure and dry. Restore power only after the fixture is closed, then test one known-good E26 lamp. If that lamp works, the original bulb was the failure. If it does not, return power to off and inspect the socket and post wiring. This simple sequence prevents a common mistake: replacing a complete PL126BK because of a bulb or connection fault that could have been isolated in minutes.