Confirmed model facts before you start
The surviving manual identifies item 0010067 as model DHO005-R1-BB-A1 and describes it as a 10-inch hanging globe solar light.
The manual calls for a rechargeable AA Ni-Cd or Ni-MH replacement battery with at least 200 mAh capacity.
For initial or recovery charging, the manual recommends 10–12 hours of full sunlight and multiple charge/discharge cycles before judging maximum battery capacity.
Before ordering anything, compare the label and physical dimensions with the Portfolio model lookup, model parts directory and parts hub.
Start with the battery before blaming the LED
A solar globe that glows weakly for a short time is usually giving you a different clue than a globe that never turns on. Short runtime after a sunny day points first toward an aged rechargeable cell, dirty solar panel, shade during the charging window or poor battery contact. A completely dead unit can still be battery-related, but also inspect the compartment contacts and the small isolation tab if the light has never operated. Use only a rechargeable AA cell of the chemistry and voltage class intended for solar charging; an ordinary disposable alkaline cell is not a service replacement.
Field note: Work from the symptom toward the failed component. Record what changes after each test instead of replacing several parts at once. That preserves the evidence you need to tell a fixture fault from a wiring, mounting, charging or control problem on 0010067 / DHO005-R1-BB-A1.
Use a controlled daylight test
Move the globe temporarily to an open location that receives unobstructed sun for most of the day. Clean the solar surface with water and a soft cloth, charge it for a full day, then cover the solar panel at dusk to simulate darkness. If it illuminates during the covered-panel test but fails in its normal location, the fixture is probably healthy and the site is the problem. Porch roofs, tree leaves, eaves and north-facing hanging locations can reduce charging far more than owners expect.
Field note: Work from the symptom toward the failed component. Record what changes after each test instead of replacing several parts at once. That preserves the evidence you need to tell a fixture fault from a wiring, mounting, charging or control problem on 0010067 / DHO005-R1-BB-A1.
Diagnose a light that works only for minutes
Runtime is the most useful field measurement on this model. Record the time it turns on and when it becomes visibly dim. Repeat after another full sunny day. If runtime remains very short, replace the rechargeable AA battery with a compatible cell and repeat the same test. If the new battery improves runtime, the original battery had lost capacity. If nothing changes, inspect charging exposure and the solar-panel/housing assembly rather than continuing to buy batteries.
Field note: Work from the symptom toward the failed component. Record what changes after each test instead of replacing several parts at once. That preserves the evidence you need to tell a fixture fault from a wiring, mounting, charging or control problem on 0010067 / DHO005-R1-BB-A1.
Globe and hanging hardware problems
The globe is not just decorative; it shields the electronics and defines how the light hangs. Cracks, missing retainers or a loose top housing can let water reach the battery compartment. If the globe itself is damaged and an exact replacement cannot be found, measure its outside diameter, neck/opening dimensions and the way it locks to the top housing before considering a donor fixture. Do not suspend the light from improvised electrical wire or from a cracked plastic hanger.
Field note: Work from the symptom toward the failed component. Record what changes after each test instead of replacing several parts at once. That preserves the evidence you need to tell a fixture fault from a wiring, mounting, charging or control problem on 0010067 / DHO005-R1-BB-A1.
Winter recovery and storage
Snow, leaf debris and long periods of low sun can leave the rechargeable cell deeply discharged. The manual specifically calls for clearing snow and allowing a long direct-sun recharge after extended coverage. For seasonal storage, remove the battery if the fixture will sit unused for months, clean the contacts and store the globe where freezing water cannot collect inside it. When returning it to service, treat the first several nights as battery-conditioning cycles rather than assuming the light has failed after one cloudy day.
Field note: Work from the symptom toward the failed component. Record what changes after each test instead of replacing several parts at once. That preserves the evidence you need to tell a fixture fault from a wiring, mounting, charging or control problem on 0010067 / DHO005-R1-BB-A1.
When replacement is smarter
Replace the complete solar globe when the housing no longer seals, the solar panel is physically delaminated, the battery compartment is heavily corroded, the hanging structure is unsafe or a known-good rechargeable battery cannot restore charging and nighttime operation. Preserve the old fixture until the replacement is installed; its globe dimensions, hanger geometry and label are valuable compatibility references.
Field note: Work from the symptom toward the failed component. Record what changes after each test instead of replacing several parts at once. That preserves the evidence you need to tell a fixture fault from a wiring, mounting, charging or control problem on 0010067 / DHO005-R1-BB-A1.
Symptom-to-fix table
Completely deadConfirm source power or solar charge, then test the simplest serviceable component before opening the housing.IntermittentLook for loose contacts, corrosion, moisture, weak battery or wiring that changes when the fixture moves.Dim outputCheck lamp/battery condition, dirty optical surfaces, voltage/charge availability and heat or corrosion at contacts.Water insideDisconnect power where applicable, dry the fixture, identify the entry path and replace damaged electrical parts before reuse.Broken mountingMeasure original geometry and hardware; do not let improvised mounting create a falling-fixture or water-entry hazard.
This record is especially valuable when factory replacement parts are discontinued because it lets you compare a modern substitute by function and dimensions instead of by appearance alone.
How to document a discontinued Portfolio fixture
LabelPhotograph the full model/item number before cleaning the label.ElectricalRecord voltage, bulb/battery type and any wattage or chemistry markings.MechanicalMeasure mounting diameter, backplate/post fit, screw spacing and visible part dimensions.ConditionPhotograph corrosion, cracks, water tracks and heat discoloration before disassembly.ReplacementKeep the original until the new part is installed so you can compare fit directly.
This record is especially valuable when factory replacement parts are discontinued because it lets you compare a modern substitute by function and dimensions instead of by appearance alone.
Related Portfolio repair resources
Continue with Portfolio troubleshooting, replacement parts, manuals, discontinued Portfolio lighting and the technical archive.